When given a bundle of optical cables, the most common question engineers often ask is whether it is single-mode or multi-mode. There is not much difference in appearance between the two, but it determines how far it can run, which type of optical module it is equipped with, and the budget of the entire link. Let's break down the differences into core diameter, dispersion, distance and cost.

The core diameter is one step different, and the number of propagation modes is much different.

The core diameter of single-mode optical fiber is generally 9 microns, and the outer cladding is 125 microns, allowing only the fundamental mode to propagate; multimode is commonly 50/125 microns (OM3, OM4), and in the early days there were 62.5/125 microns. A large core diameter means that there are a large number of modes propagating at the same time. Each mode takes a different path length and reaches the receiving end in sequence.

What determines the upper limit of distance is modal dispersion

Multimode distance is stuck on dispersion, not just fiber attenuation. Under the 850nm window, OM3 Gigabit is usually designed for 300 meters and OM4 for 400 meters. The bit error rate starts to rise further. Single mode has no modal dispersion, and the main factors limiting the distance become attenuation and chromatic dispersion, so nominal values such as 10 kilometers per gigabit, 20 kilometers per 100 gigabit and even 40 kilometers per 100 gigabit appear on the single-mode side, for exampleSFP Gigabit single mode dual fiber 10KM optical module and SFP Gigabit Multimode Dual Fiber Optical ModuleThese are two typical combinations.

When is multimode more appropriate?

  • The distance from cabinet to cabinet and switch to server in the computer room is basically within 100 meters.
  • Modules and jumpers are budget-sensitive, and multi-mode modules and OM3 jumpers have lower unit prices.
  • The backbone in the building may be replaced with copper cables or high-speed cables in the future, as long as the optical cable redundancy is sufficient.

There is no need to use optical fiber within three meters of the cabinet in the data center interconnection.Data center high-speed interconnection solutionDAC or AOC in. When judging existing lines, it is more reliable to look at the printing on the optical cable sheath (OS1 and OS2 are single-mode, OM1 to OM4 are multi-mode) than guessing based on the color; if you are not sure, you can contact EB-LINK technical support for assistance in checking, call 0755-83179002.